Breaking Down How to Use Magnetic Flux Indicators and QQIs

In this article, Magnetic Particle Inspection Flux Indicator Strips and Quantitative Quality Indicators (QQI) are defined and given a user manual approach to find artificial flaw standards

By David Geis, Product Manager

  •  

Magnetic particle test pieces will help you maintain your mag particle process by verifying magnetic particle performance. Use to check for mag particle deterioration, to compare different magnetic powders, to verify sensitivity or visibility or to assure field direction and strength. In this blog we look at the primary use of Quantitative Quality Indicators (QQIs) and Magnetic Flux Indicators which are to verify field direction and strength.

Field strength and orientation are key factors in a successful magnetic particle examination. Sufficient magnetic field must be present to form indications on the surface being examined. And because magnetism is directional in nature, only discontinuities that cross the lines of flux will produce leakage fields to form those indications.

Unfortunately, the magnetic field within the part cannot be measured directly. So many practitioners use artificial flaws or test pieces to confirm magnetic field strength. At the same time, artificial flaws can confirm direction since only those orthogonal to the lines of flux will form indications. The most common artificial flaws in use are QQIs and Flux Indicator Strips. Each has its own advantages and disadvantages to consider when choosing the right tool for your inspection.

 

Quantitative Quality Indicators (QQI)

QQIs are artificial flaw notched shims that are attached to example parts, commonly used to demonstrate both field strength and direction within a part. Available in several different configurations, QQIs are thin steel shims with etched patterns in circular and cross shapes to provide indications in all directions. The steel alloy and notch dimensions, as specified in AS 5371, are designed to provide indications when the base part is magnetized to at least 30 gauss. The thin shims can conform to curved part surfaces, and they are typically affixed to a part using permanent adhesives.

QQIs are useful for setting up the magnetization parameters for part-specific techniques and can be used to create an example part for the daily system performance check of the magnetizing equipment. They are very important for the setup and balance of multi-directional fields, since they have circular flaws that show indications in all directions simultaneously.

 

Advantages

  • Thin and flexible, conform to the contours of the part surface
  • Notches in multiple directions to show both longitudinal and circular fields
  • Notch dimensions defined to produce results with 30 gauss magnetization
  • Circular notches can be used with multi-directional fields

 

Disadvantages

  • Single-use, permanently attached to part surface
  • Must thoroughly clean shim and part surface before using
  • Fragile, can easily be damaged while handling or during user
  • Susceptible to corrosion and rust

 

How to Use

Remove the corrosion-resistant film from the QQI before use. Solvents such as SKC-S, acetone, or an adhesive remover, Goof-Off or equivalent, are recommended. Use caution when handling to prevent damage or distortion. QQIs must be placed in intimate contact with the notches facing inward towards the part surface. Permanent adhesive such as cyanoacrylate, super glue or equivalent, is recommended. Attach the QQI conforming to the part surface with no gaps or loose areas. No adhesive should remain on the outer inspection surface after the QQI is attached. Cellophane tape, Scotch Brand 191, 471, or 600 series, may be used to attach QQIs. Care should be taken to only cover the edges of the QQI so that the central notched area is clear. If the tape becomes loose, completely remove the QQI, clean and reattach with new tape.

 

Magnetic Flux Indicators

Laminated Magnetic Flux Strips, also known as Type G Burmah-Castrol Strips, have a core of high-permeability steel with brass cladding 0.002 in / 0.05 mm thick on both sides. The core material has three slots of different widths, providing discontinuities that show as linear indications in a magnetic field. The strips are commonly used with wet visible materials for power pack equipment and yoke inspections but can also be used with dry magnetic powders. Laminated Magnetic Flux Strips are stiffer than QQIs, and do not conform to curved surfaces easily. But unlike QQIs, laminated Magnetic Flux Strips are not permanently affixed to a part, so they can be reused for multiple applications. Because they form linear indications in only one direction, laminated Magnetic Flux Strips are not suitable for use with multi-directional magnetization.

 

Advantages

  • Not permanently attached to part surface
  • Indicates flux on the actual surface being examined, not a separate test piece
  • No cleaning or preparation required
  • Brass cladding protects against corrosion

 

Disadvantages

  • Minimal flexibility, does not conform to contoured surfaces
  • Linear notches in one direction only
  • Not sufficient to demonstrate magnetic field strength
  • Not for use with multi-directional fields

 

How to Use

Place the Flux Indicator Strip in intimate contact with the area to be examined. The strip may be held in place manually or with the use of an adhesive or tape. Do not cover the center of the strip with tape because that will prevent formation of indications. Flux indicator strips provide the strongest indications when positioned so that the long dimension is perpendicular to the applied magnetic field. After the strip is positioned, energize the magnetic field and apply magnetic particles (wet suspension or dry powder). Indications perpendicular to the magnetic flux will be stronger and more well defined than indications at an angle. No indications will form if the strip is aligned parallel to (in line with) the magnetic flux.

The most important point to remember when using Flux Indicator Strips is that they may only be used to demonstrate the direction of magnetic flux, not the field strength. Determining the strength of the magnetic field requires a part with known discontinuities, the use of QQIs, or direct measurement using a calibrated gauss meter. For more detailed instructions on the use of QQIs and Flux Indicator Strips, please refer to ASTM E709, E1444, and E3024.

 

Published August 7, 2018

Please wait while we gather your results.

Related Blog Entries

Magnetic Particle Inspection Demo

How to Do Visible Magnetic Particle Inspections

See an overview of visible, dry-method magnetic particle inspection method according to ASTM E1444.

Read More...

The most common incorrect assumptions about magnetic particle inspection

10 Misunderstandings about Magnetic Particle Testing

This article discusses the most common incorrect assumptions about magnetic particle inspection and gives you some solutions to combat these misunderstandings

Read More...

Subscribe to Magnaflux News:

Magnaflux

155 Harlem Avenue
Glenview, IL 60025, USA
Telephone: +1 847-657-5300
Contact Magnaflux Customer Service

Select Your Country North America Mexico Brazil China Europe India New Zealand, Australia, Japan, Southeast Asia
© 2024 Magnaflux - All Rights Reserved.